Frequently Asked Questions...
20 amp heater not put on 30 amp breaker?
The breaker is meant to protect the wires, as the heater should have # 12 AWG for 20 amps and a 30 amp breaker is meant to protect wire of #10 AWG you could have a fire hazard.
Replace the 30 amp breakers with 20 amp breaker and you will be safe
Answer:
Is there a question here?
Update:
Ralph is correct in his concept. But, the correct figure is 16amps max for a 20 amp circuit. For a known resistive load (as would be the case with a heat circuit), you are only allowed to load the circuit to 80% of breaker size. Therefore, a heater that uses a full 20 amps would, in fact, be required to have at least a 25 amp breaker. Although available, these are not as common. Since you would still be required to have #10 wire, a 30 amp breaker is acceptable.
30 Breaker
Breaker High - He Shoots, He Scores - Part 1
Power Distribution System For Taipei 101, Hsuehshan Tunnel - Circuit Breaker. Magnetic Switch
ver the past six years, Taipei 101 has been dazzling people with spectacular fireworks. When the audience starts to count down, every timer to set off the fireworks is precisely controlled by a magnetic switch at each floor. A low quality magnetic contactor can trigger the timer to set off the fireworks too early or too late and result in disaster. The reason that Shihlin Electric was selected to be the partner for such an important job is because of their switchgear reliability and over 50 years of experience. As a result, magnetic switch (S-P11) for fireworks launched successfully from Taipei 101 skyscraper on New Year's Eve broadcasts, and Shihlin Electric's relentlessness in designing good power distribution systems paid off.
Taiwan Hsuehshan Tunnel's Usage of Shihlin Electric's Magnetic Switch, Circuit Breaker Products
Hsuehshan Tunnel is the longest underground road tunnel in Asia, and it is also the 5th longest tunnel in the world, at nearly 13km (8 miles) long. Again, Shihlin Electric was chosen to set up the magnetic switch power distribution system for this long tunnel, which many factors are needed to be considered such as the humidity level, the maintain system and the long-life stability of magnetic switch.
he selection of Shihlin Electric's magnetic switch (S-P21) was due to their superior products preventing the humidity in the tunnel. As we know, high temperatures and humidity are the major factors affecting lights' stability and life cycle. Shihlin Electric's magnetic contactors have international certification including UL, CSA, TUV, which means they are suitable for JIS, JEM, IEC, EN and VDE, and their magnetic switches' high flexibility for various types of uses is also one of their great advantages.
PS. Every circuit breaker, magnetic switch is tested under imitated circumstances, including temperature, humidity and vibration tests in various environments
Shihlin Electric is a Taiwanese multinational conglomerate corporation that has been providing power distribution system and products globally. Shihlin Electric began to work with Mitsubishi Group 30 years ago for circuit breakers (CB) and magnetic switch (MS)'s development, based on rules to meet Taiwan market, and their circuit breaker and magnetic switch is built with international standards.
http://circuit-breaker.ready-online.com/magnetic-switch.html
About the Author
Here are a list of other products on Electrical Engineering Equipment Company, come check these out: