Square Amp Circuit Breaker

wordpress plugins and themes automotive,business,crime,health,life,politics,science,technology,travel

Thanks for visiting Electrical Engineering Equipment Company. Please remember to bookmark this page Square Amp Circuit Breaker. If you found what your looking for, then don"t forget to click an appreciation button above for this post.

Square D 20 amp circuit breaker FDA140203 I-Line
Square D 20 amp circuit breaker FDA140203 I-Line
US $102.75
**NEW** SQUARE D MAG-GUARD  ADJUSTABLE TRIP  CIRCUIT BREAKER  7 AMP FHP3600712M
**NEW** SQUARE D MAG-GUARD ADJUSTABLE TRIP CIRCUIT BREAKER 7 AMP FHP3600712M
US $34.95
Square D 40 Amp Circuit Breaker ; Cat. # FCP34040
Square D 40 Amp Circuit Breaker ; Cat. # FCP34040
US $187.50
Square D QOB 80AMP 240V 2 POLE Circuit Breaker QOB380 80A 240V 2P
Square D QOB 80AMP 240V 2 POLE Circuit Breaker QOB380 80A 240V 2P
US $65.00
SQUARE D 1200 AMP I-LINE CIRCUIT BREAKER NX361200
SQUARE D 1200 AMP I-LINE CIRCUIT BREAKER NX361200
US $1,800.00
Square D 30 Amp Circuit Breaker FJA240302 I-Line
Square D 30 Amp Circuit Breaker FJA240302 I-Line
US $525.00
Square D 20Amp Circuit Breaker 240VAC 1 Pole
Square D 20Amp Circuit Breaker 240VAC 1 Pole
US $11.24
SQUARE D CIRCUIT BREAKER 3 POLE 600 Volt 600 AMP
SQUARE D CIRCUIT BREAKER 3 POLE 600 Volt 600 AMP
US $599.00
Square D HOM 30AMP 120/240V 2 POLE Circuit Breaker HOM230 30A 120/240V 2P
Square D HOM 30AMP 120/240V 2 POLE Circuit Breaker HOM230 30A 120/240V 2P
US $25.00
Square D Type QO HK-57 50Amp Circuit Breaker 240VAC
Square D Type QO HK-57 50Amp Circuit Breaker 240VAC
US $17.24
Square D Type QO 30 Amp Circuit Breaker 2Pole 240 VAC
Square D Type QO 30 Amp Circuit Breaker 2Pole 240 VAC
US $14.99
Square D QO 100AMP 240V 2 POLE Circuit Breaker QO2100 100A 240V 2P
Square D QO 100AMP 240V 2 POLE Circuit Breaker QO2100 100A 240V 2P
US $70.00
Square D QOB 100AMP 120/240V 2 POLE Circuit Breaker QOB2100 100A 120/240V 2P
Square D QOB 100AMP 120/240V 2 POLE Circuit Breaker QOB2100 100A 120/240V 2P
US $70.00
Square D 15 Amp, I-Line Circuit Breaker, FA34015, Used, Warranty
Square D 15 Amp, I-Line Circuit Breaker, FA34015, Used, Warranty
US $25.00
Square D 15amp I Line circuit breaker
Square D 15amp I Line circuit breaker
US $67.00
Square D 20amp Thermal Magnetic Circuit Breaker I-LINE
Square D 20amp Thermal Magnetic Circuit Breaker I-LINE
US $67.00
Square D #HOM280 Circuit Breaker, 2 Pole, 80 Amp, NIB
Square D #HOM280 Circuit Breaker, 2 Pole, 80 Amp, NIB
US $37.00
Square D QO8 20Amp Circuit Breaker 240VAC 2Pole
Square D QO8 20Amp Circuit Breaker 240VAC 2Pole
US $18.74
SQUARE D  40 AMP 3 POLE   I-LINE CIRCUIT BREAKER    FA36040      K-24B
SQUARE D 40 AMP 3 POLE I-LINE CIRCUIT BREAKER FA36040 K-24B
US $42.50
Square D Circuit Breaker, 225 Amp 997327 #28407
Square D Circuit Breaker, 225 Amp 997327 #28407
US $350.00
Square D Circuit Breaker, 225 Amp 997300, #28408
Square D Circuit Breaker, 225 Amp 997300, #28408
US $299.99
**NEW** SQUARE D CIRCUIT BREAKER  70 AMP  600 VOLTS AC FAL36070 SERIES 2
**NEW** SQUARE D CIRCUIT BREAKER 70 AMP 600 VOLTS AC FAL36070 SERIES 2
US $54.95
Square D Circuit Breaker 400 Amp LAF3640036MUG27 #28414
Square D Circuit Breaker 400 Amp LAF3640036MUG27 #28414
US $1,299.00
3 USED SQUARE D CIRCUIT BREAKER FY14020A 20 AMP
3 USED SQUARE D CIRCUIT BREAKER FY14020A 20 AMP
US $49.00
USED SQUARE D CIRCUIT BREAKER FA36040 40 AMP
USED SQUARE D CIRCUIT BREAKER FA36040 40 AMP
US $59.00
square d 20 amp 1 pole circuit breaker 992120 ML-120
square d 20 amp 1 pole circuit breaker 992120 ML-120
US $12.99
USED SQUARE D CIRCUIT BREAKER FA36100 100 AMP
USED SQUARE D CIRCUIT BREAKER FA36100 100 AMP
US $119.00
Square D FAL34015 15 Amp Circuit Breaker
Square D FAL34015 15 Amp Circuit Breaker
US $10.00
SQUARE D QO 3 POLE MC-1404 HACR 50AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE MC-1404 HACR 50AMP CIRCUIT BREAKER
US $40.00
USED PULLOUT SQUARE D CIRCUIT BREAKER FHP3600311M 3 AMP
USED PULLOUT SQUARE D CIRCUIT BREAKER FHP3600311M 3 AMP
US $69.00
SQUARE D QO 3 POLE RV-2291 HACR 30AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE RV-2291 HACR 30AMP CIRCUIT BREAKER
US $20.00
SQUARE D QO 3 POLE LK-5921 HACR 30AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE LK-5921 HACR 30AMP CIRCUIT BREAKER
US $20.00
SQUARE D QO 3 POLE MJ-3693 HACR 60AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE MJ-3693 HACR 60AMP CIRCUIT BREAKER
US $40.00
Square D 3P 70 Amp Q1B370 Circuit Breaker
Square D 3P 70 Amp Q1B370 Circuit Breaker
US $49.99
SQUARE D QO 3 POLE LL-9296 HACR 30AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE LL-9296 HACR 30AMP CIRCUIT BREAKER
US $20.00
SQUARE D KA KA36250 3 POLE 250 AMP 600V CIRCUIT BREAKER GREY
SQUARE D KA KA36250 3 POLE 250 AMP 600V CIRCUIT BREAKER GREY
US $499.00
SQUARE D 30 AMP EHD CIRCUIT BREAKER EHD34030 BOLT IN
SQUARE D 30 AMP EHD CIRCUIT BREAKER EHD34030 BOLT IN
US $145.00
Square D LAP36400MB  400 amp 600 volt main circuit breaker
Square D LAP36400MB 400 amp 600 volt main circuit breaker
US $189.99
SQUARE D QO 3 POLE NE-6263/NE-6295 HACR 60AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE NE-6263/NE-6295 HACR 60AMP CIRCUIT BREAKER
US $40.00
NEW SQUARE D FA32040 TYPE FA CIRCUIT BREAKER 3 POLE 40 AMP
NEW SQUARE D FA32040 TYPE FA CIRCUIT BREAKER 3 POLE 40 AMP
US $80.00
SQUARE D QO 3 POLE LL-7378 HACR 50AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE LL-7378 HACR 50AMP CIRCUIT BREAKER
US $20.00
SQUARE D 20 AMP  3 POLE CIRCUIT BREAKER     FA34020      ZAA-83
SQUARE D 20 AMP 3 POLE CIRCUIT BREAKER FA34020 ZAA-83
US $42.50
Q1B370 Square D Circuit Breaker, 3 Pole 70 Amp Bolt In, Guaranteed to work
Q1B370 Square D Circuit Breaker, 3 Pole 70 Amp Bolt In, Guaranteed to work
US $34.65
10 SQUARE D HOM115 HOMELINE 15-AMP 1-POLE CIRCUIT BREAKER LOT USED
10 SQUARE D HOM115 HOMELINE 15-AMP 1-POLE CIRCUIT BREAKER LOT USED
US $19.99
1 NEW SQUARE D JJA36250 250 AMP 3 POLE 600 VOLTS CIRCUIT BREAKER
1 NEW SQUARE D JJA36250 250 AMP 3 POLE 600 VOLTS CIRCUIT BREAKER
US $1,150.00
Square D KHL3622522DC2315 Circuit Breaker 225 amp USED
Square D KHL3622522DC2315 Circuit Breaker 225 amp USED
US $500.00
SQUARE D QO 3 POLE LM-3584 HACR 30AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE LM-3584 HACR 30AMP CIRCUIT BREAKER
US $20.00
SQUARE D 15 AMP 10kA 240V  CIRCUIT BREAKER 2 PIECE SET
SQUARE D 15 AMP 10kA 240V CIRCUIT BREAKER 2 PIECE SET
US $14.00
SQUARE D EDB34025 3 POLE 25 AMP 480 VOLT CIRCUIT BREAKER
SQUARE D EDB34025 3 POLE 25 AMP 480 VOLT CIRCUIT BREAKER
US $89.95
NIB SQUARE D FAL26020 CIRCUIT BREAKER 20 AMP SERIES *
NIB SQUARE D FAL26020 CIRCUIT BREAKER 20 AMP SERIES *
US $140.00
SQUARE D QO 3 POLE LL-4347 HACR 60AMP CIRCUIT BREAKER
SQUARE D QO 3 POLE LL-4347 HACR 60AMP CIRCUIT BREAKER
US $20.00
SQUARE D LA36300 300 AMP CIRCUIT BREAKER
SQUARE D LA36300 300 AMP CIRCUIT BREAKER
US $350.00
SQUARE D CIRCUIT BREAKER 250 AMP 600 VOLT
SQUARE D CIRCUIT BREAKER 250 AMP 600 VOLT
US $49.00
SQUARE D 20 AMP 1 POLE CIRCUIT BREAKER  TYPE FH 20 A        FH16020B        B-17
SQUARE D 20 AMP 1 POLE CIRCUIT BREAKER TYPE FH 20 A FH16020B B-17
US $26.50
Square D QOB CIRCUIT BREAKER 1 Pole 25 Amp QOB125 Bolt On 120/240 Volt
Square D QOB CIRCUIT BREAKER 1 Pole 25 Amp QOB125 Bolt On 120/240 Volt
US $2.99
NEW SQUARE D 20 AMP 1 POLE CIRCUIT BREAKER  TYPE QO     QO120C          G-47
NEW SQUARE D 20 AMP 1 POLE CIRCUIT BREAKER TYPE QO QO120C G-47
US $8.50
NEW IN BOX SQUARE D FAL32020 CIRCUIT BREAKER 3 POLE 20 AMP
NEW IN BOX SQUARE D FAL32020 CIRCUIT BREAKER 3 POLE 20 AMP
US $38.00
SQUARE D  MAG-GUARD TRIP CIRCUIT BREAKER 15 AMP CAT NO.FAL3601513M
SQUARE D MAG-GUARD TRIP CIRCUIT BREAKER 15 AMP CAT NO.FAL3601513M
US $15.00
NEW Square D FA34015 Circuit Breaker 3 pole 15 amp 480 volt
NEW Square D FA34015 Circuit Breaker 3 pole 15 amp 480 volt
US $291.55
NEW Square D FA34020 Circuit Breaker 3 pole 20 amp 480 volt
NEW Square D FA34020 Circuit Breaker 3 pole 20 amp 480 volt
US $291.55
NEW Square D FA34030 Circuit Breaker 3 pole 30 amp 480 volt
NEW Square D FA34030 Circuit Breaker 3 pole 30 amp 480 volt
US $291.55
NEW Square D FA34050 Circuit Breaker 3 pole 50 amp 480 volt
NEW Square D FA34050 Circuit Breaker 3 pole 50 amp 480 volt
US $291.55
1 NIB SQUARE D HJA36025 25 AMP 3 POLE 600 VOLTS CIRCUIT BREAKER
1 NIB SQUARE D HJA36025 25 AMP 3 POLE 600 VOLTS CIRCUIT BREAKER
US $385.50
NEW Square D FA34070 Circuit Breaker 3 pole 70 amp 480 volt
NEW Square D FA34070 Circuit Breaker 3 pole 70 amp 480 volt
US $348.60
SQUARE D 10 AMP 10kA 120/240 V CIRCUIT BREAKER
SQUARE D 10 AMP 10kA 120/240 V CIRCUIT BREAKER
US $5.00
NEW Square D FA34080 Circuit Breaker 3 pole 80 amp 480 volt
NEW Square D FA34080 Circuit Breaker 3 pole 80 amp 480 volt
US $348.60
NEW Square D FA34090 Circuit Breaker 3 pole 90 amp 480 volt
NEW Square D FA34090 Circuit Breaker 3 pole 90 amp 480 volt
US $348.60
Square D QO120 / 1 pole - 20 amp circuit breaker
Square D QO120 / 1 pole - 20 amp circuit breaker
US $1.50
Square D QO115 / 1 pole - 15 amp circuit breaker
Square D QO115 / 1 pole - 15 amp circuit breaker
US $1.50
SQUARE D 200 AMP CIRCUIT BREAKER; USED, GOOD CONDITION
SQUARE D 200 AMP CIRCUIT BREAKER; USED, GOOD CONDITION
US $100.00
Square D Circuit Breaker KAL-36150, 150 Amps, #5456
Square D Circuit Breaker KAL-36150, 150 Amps, #5456
US $199.99
NEW IN BOX SQUARE D Q2L3175 MOLDED CASE CIRCUIT BREAKER 3 POLE 175 AMP TYPE Q2L
NEW IN BOX SQUARE D Q2L3175 MOLDED CASE CIRCUIT BREAKER 3 POLE 175 AMP TYPE Q2L
US $108.00
NEW Square D FA36015 Circuit Breaker 3 pole 15 amp 600 volt
NEW Square D FA36015 Circuit Breaker 3 pole 15 amp 600 volt
US $339.85
Square D EDB34015 3pole 15amp 480v circuit breaker New
Square D EDB34015 3pole 15amp 480v circuit breaker New
US $187.00
Square D FAL36015 Gray lable 15 amp lug in lug out Circuit Breaker 3Pole Great
Square D FAL36015 Gray lable 15 amp lug in lug out Circuit Breaker 3Pole Great
US $30.00
Square D FAL34015 Gray lable 15 amp lug in lugout Circuit Breaker 3Pole Great
Square D FAL34015 Gray lable 15 amp lug in lugout Circuit Breaker 3Pole Great
US $35.00
SQUARE D Y1B120 E05T1 CIRCUIT BREAKER 20 AMP
SQUARE D Y1B120 E05T1 CIRCUIT BREAKER 20 AMP
US $29.00
NEW Square D FA36020 Circuit Breaker 3 pole 20 amp 600 volt
NEW Square D FA36020 Circuit Breaker 3 pole 20 amp 600 volt
US $339.85
Square D FAL34015 Gray lable 15 amp lug in lugout Circuit Breaker 3Pole Good
Square D FAL34015 Gray lable 15 amp lug in lugout Circuit Breaker 3Pole Good
US $35.00
Square D LH36300 Circuit Breaker, 300 Amp, I-Line, 600V
Square D LH36300 Circuit Breaker, 300 Amp, I-Line, 600V
US $635.00
Square D FAL26015 Gray lable 15 amp lug in lugout Circuit Breaker 2Pole Great
Square D FAL26015 Gray lable 15 amp lug in lugout Circuit Breaker 2Pole Great
US $30.00
SQUARE(D) Q1L3100 100AMP 240V 3POLES CIRCUIT BREAKER
SQUARE(D) Q1L3100 100AMP 240V 3POLES CIRCUIT BREAKER
US $125.00
Square D FAL36030 Gray lable 30 amp lug in lugout Circuit Breaker 3Pole Great
Square D FAL36030 Gray lable 30 amp lug in lugout Circuit Breaker 3Pole Great
US $40.00
Square D I line 2 POLE CIRCUIT BREAKER 30 amps 600volt
Square D I line 2 POLE CIRCUIT BREAKER 30 amps 600volt
US $59.00
Square D JGL36150 Circuit Breaker, 150 Amp, 600 V, 35 kAIR, Lugs Both Ends, NEW
Square D JGL36150 Circuit Breaker, 150 Amp, 600 V, 35 kAIR, Lugs Both Ends, NEW
US $595.00
SQUARE D CIRCUIT BREAKER 3P 200 AMP 600V LUG/LUG KAL36200
SQUARE D CIRCUIT BREAKER 3P 200 AMP 600V LUG/LUG KAL36200
US $325.00
Square D FAL32035 Black Frame 30 amp lug in lugout Circuit Breaker 3Pole Great
Square D FAL32035 Black Frame 30 amp lug in lugout Circuit Breaker 3Pole Great
US $35.00
NEW Square D FA36030 Circuit Breaker 3 pole 30 amp 600 volt
NEW Square D FA36030 Circuit Breaker 3 pole 30 amp 600 volt
US $339.85

Square Amp Circuit Breaker

Grounding Transformers

Grounding is clearly one of the most important aspects of electrical design, but it steadfastly continues to be misinterpreted and misunderstood. Millions of dollars in liability and loss can be attributed to ground-fault arcing; thus, grounding-related issues should top the checklists of any electrical contractor.
Grounding Transformers:

Simply put, a grounding transformer is used to provide a ground path to either an ungrounded "Y" or a delta connected system. Grounding transformers are typically used to:

  1. Provide a relatively low impedance path to ground, thereby maintaining the system neutral at or near ground potential
  2. Limit the magnitude of transient over voltages when re-striking ground faults occur
  3. Provide a source of ground fault current during line-to-ground faults
  4. Permit the connection of phase to neutral loads when desired

If a single line-to-ground fault occurs on an ungrounded or isolated system, no return path exists for the fault current, thus no current flows. The system will continue to operate but the other two un-faulted lines will rise in voltage by the square root of 3, resulting in overstressing of the transformer insulation and other associated components on the system by 173%. MOV lightning arresters are particularly susceptible to damage from heating by leakage across the blocks even if the voltage increase is not sufficient to flash over. A grounding transformer provides a ground path to prevent this.

Large multi-turbine wind farms provide an example of the use of grounding transformers for fault protection on ungrounded lines. In many wind farms the substation transformer provides the sole ground source for the distribution system. When a ground fault on a collector cable causes the substation circuit breaker for that cable to open, the wind turbine string becomes isolated from the ground source. The turbines do not always detect this fault or the fact that the string is isolated and ungrounded; thus the generators continue to energize the collector cable, and the voltages between the un-faulted cables and the ground rise far above the normal voltage magnitude as described above. A grounding transformer placed on the turbine string provides a ground path in the event the string becomes isolated from the system ground.

Construction:

Grounding transformers are normally constructed either with

  1. A ZigZag (Zn) connected winding with or without an auxiliary winding or
  2. As a Wye (Ynd) connected winding with a delta connected secondary that may or may not be used to supply auxiliary power

The geometry of the Zig-Zag connection is useful to limit circulation of third harmonics and can be used without a Delta connected winding or the 4- or 5-leg core design normally used for this purpose in distribution and power transformers. Eliminating the need for a secondary winding can make this option both less expensive and smaller than a comparable two-winding grounding transformer. Furthermore, use of a Zig-Zag transformer provides grounding with a smaller unit than a two-winding Wye-Delta transformer providing the same zero sequence impedance.

Wye connected grounding transformers, on the other hand, require either a delta connected secondary or the application of 4 or 5 leg core construction to provide a return flux path for unbalanced loading associated with this primary connection. Since it is often desirable to provide auxiliary power from the grounding transformer secondary winding, this benefit can sway the end user to specify a two-winding grounding transformer in lieu of a Zig-Zag connection. The current trend in wind farm designs is toward the Wye connected primary with a delta secondary.

It is important to understand that both Zig-Zag and two-winding grounding transformers can be provided with the ability to provide auxiliary power, and this can be either a Wye or Delta connected load.

A solidly grounded system using a grounding transformer offers many safety improvements over an ungrounded system. However, the ground transformer alone lacks the current limiting ability of a resistive grounding system. For this reason, neutral ground resistors are often used in conjunction with the grounding transformer to limit neutral ground fault current magnitude. Their ohm values should be specified to allow high enough ground fault current flow to permit reliable operation of the protective relaying equipment, but low enough to limit thermal damage.

How to Specify a Grounding Transformer

The basic parameters required for quoting a grounding transformer are:

  • Primary Voltage - This is the system voltage to which the grounded winding is to be connected. Don't forget to specify the BIL also. In some cases the BIL will be dictated by equipment considerations, such as 150 kV BIL ratings on 34500 volt wind farms because of the limitation on dead front connectors.
  • Rated KVA - Because the grounding transformer is normally a short time device, its size and cost are less when compared with a continuous duty transformer of equal kVA rating. For this reason, grounding transformers are often not sized by "kVA" but by their continuous and short time current ratings. Regardless of how you rate it, the grounding transformer must be sized to carry the rated continuous primary phase current without exceeding its temperature limit. This load includes the magnetizing current of the core, the capacitive charging current for the cables, and any auxiliary load if applicable.  The higher this value, the larger and more costly the transformer will be.  Typical continuous current values can be as low as 5 amps to as high as a few hundred. Be sure to include any auxiliary loading requirements.
  • Continuous Neutral Current - The continuous neutral current is defined as three times the phase to current, or in other words, the zero sequence current. This is usually considered to be zero if the system is balanced. However, for the purposes of designing a grounding transformer, it is a value that is expected to flow in the neutral circuit without tripping protective circuits (which would force the current to be zero) or the leakage current to ground that is not a symmetrical function. Again this value is needed to design for thermal capacity of the grounding transformer.
  • Fault current and duration - This value is needed to calculate the short time heating that results from a fault on the system and should be determined from an engineered system study. Typical values for this range from a few hundred amps to a few thousand amps with duration times expressed in seconds and not cycles. For instance, a value of 400 amps for 10 seconds is typical. The fault duration is a critical parameter for the transformer designer. Where protection schemes use the grounding transformer for tripping functions, a relatively short time duration is specified (5 -10 seconds). On the other hand, a continuous or extended neutral fault current duration would be required when the grounding transformer is used in a ground fault alarm scheme.
  • Impedance - The impedance can be expressed as a percentage or as an ohm value per phase. In either case it should be chosen so that the un-faulted phase voltages during a ground fault are within the temporary over-voltage capability of the transformer and associated equipment, such as arresters and terminal connectors. Because of this description, the values can vary from as low as 8% to almost 100%. This value must come from the system designer.
  • Primary winding connection - Specify the type of primary connection, either Zig-Zag or grounded Wye.
  • Secondary connection - specify the secondary voltage and connection when applicable.

    Specify the size of auxiliary loading to be connected for either Zn or Wye connected primary windings.

    If the option is to have a two winding transformer with no secondary load, advise if the delta winding can be "buried" (that is not brought out) or if only one bushing is to be brought out for grounding to the tank or testing.

  • Basic overall construction features - note the following features as they apply to each transformer...
    • Compartmental Padmount transformer with integral tamperproof compartment or substation design
    • Outdoor or indoor
    • Fluid type- mineral oil, silicone, Envirotemp FR3
    • Connectivity -dead front, live front, spade terminals, location of terminals - cover or  sidewall , exposed or enclosed, etc
    • Temperature rise is assumed to be 65'C
    • Site elevation or environmental concerns
    • Special paint as required
  • Neutral Ground Resistors - The rated voltage of the NGR should be equal to the line to ground voltage of the grounding transformer. The current rating and duration should match the grounding transformer ratings. Remember to set the current rating high enough to be above the cable charging current and grounding transformer magnetizing current.

About PCT

Pacific Crest Transformers is a leader in the design and construction of distribution transformer. Read more about transformers, grounding transformers and related information at PCT.

About the Author

Mike Dickinson began his carrier in transformer industry in 1972 at Pacific Crest Transformers. Currently Mike is in charge of Business Development at PCT.

Square Amp Circuit Breaker
If you are looking for a different item here are a list of related products on Electrical Engineering Equipment Company, please check out the following: